Procedure 2 Inspecting Malfunctioning Parts - CONSULT Scan Tool
Inspecting SRS malfunctioning parts by using CONSULT - Diagnosis mode1. Turn ignition switch "OFF".
2. Connect "CONSULT" to Data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "AIRBAG".
6. Touch "SELF-DIAG [CURRENT]".
7. Diagnostic codes are displayed on "SELF-DIAG [CURRENT]".
If no self-diagnostic failure is detected on "SELF-DIAG [CURRENT]" but malfunction is indicated by the "AIR BAG" warning lamp, check the battery voltage. If the battery voltage is less than 9V, charge the battery. Then go to DIAGNOSTIC PROCEDURE 4 for final checking. If the battery voltage is OK, go to DIAGNOSTIC PROCEDURE 6, to diagnose the following situations:
- Self-diagnostic failure "SELF-DIAG [PAST]" (which was previously stored in the memory) might not be erased after repairing.
- The SRS system malfunctions intermittently.
8. Touch "PRINT".
9. Compare diagnostic codes to the CONSULT DIAGNOSTIC CODE CHART.
10. Touch "BACK" key of CONSULT until "SELECT SYSTEM" appears in order to return to User mode from Diagnosis mode, then turn off CONSULT.
11. Turn ignition switch "OFF", then disconnect CONSULT and both battery cables.
12. Repair the system as outlined by the "Repair Order" in CONSULT DIAGNOSTIC CODE CHART, that corresponds to the problem code. For replacement procedure of component parts, refer to Removal and Installation - Diagnosis Sensor Unit, Seat belt Pre-Tensioner and Satellite Sensor.
13. After repairing the system, go to DIAGNOSTIC PROCEDURE 4 for final checking.
Part 1 Of 2:
Part 2 Of 2:
CONSULT DIAGNOSTIC CODE CHART ("SELF-DIAG [CURRENT]")