CONSULT Cruise Test Setting Procedure
3. CRUISE TEST DESCRIPTION- Using CONSULT, conduct a cruise test and record the results.
- Print the results and ensure that shifts and lock-ups take place as per "Shift Schedule".
- Check all items listed in Cruise Test, Parts 1 through 3.
CONSULT Setting Procedure
1. Turn off ignition switch.
2. Connect "CONSULT" to Data link connector for CONSULT. (Data link connector for CONSULT is located in the fuse box.)
3. Turn on ignition switch.
4. Touch "START".
5. Touch "A/T".
6. Touch "DATA MONITOR".
7. Touch "SETTING" to set recording condition.
8. Touch "LONG TIME" and "ENTER" key.
9. Go back to SELECT MONITOR ITEM and touch "MAIN SIGNALS".
10. Touch "START".
11. When performing cruise test, touch "RECORD".
BEGIN CRUISE TEST PART 1
Test Chart-Cruise Test Part 1 (a):
Test Chart-Cruise Test Part 1 (b):
Test Charts
12. After finishing cruise test part 1, touch "STOP".
13. Touch "DISPLAY".
14. Touch "PRINT".
15. Touch "PRINT".
16. Check the monitor data printed out.
17. Continue cruise test part 2 and 3.
CRUISE TEST PART 2
Test Chart-Cruise Test Part 2:
Test Chart
CRUISE TEST PART 3
Test Chart-Cruise Test Part 3:
Test Chart