CONSULT Cruise Test Setting Procedure
Consult Scan Tool:
PRELIMINARY CRUISE TEST WITH CONSULT
^ Using CONSULT, conduct a cruise test and record the result.
^ Print the result and ensure that shifts and lock-ups take place as per "Shift Schedule".
CONSULT SETTING PROCEDURE
1. Turn off ignition switch.
Data Link Connector Location:
2. Connect "CONSULT" to Data link connector for CONSULT.
3. Turn on ignition switch.
Consult Preliminary Checks:
4. Touch "START".
Consult Preliminary Checks:
5. Touch "A/T".
Consult Preliminary Checks:
6. Touch "DATA MONITOR".
Consult Preliminary Checks:
7. Touch "SETTING" to set recording condition.
Consult Preliminary Checks:
8. Touch "LONG TIME" and "ENTER" key.
Consult Preliminary Checks:
9. Go back to SELECT MONITOR ITEM and touch "MAIN SIGNALS".
10. Touch "START".
Consult Preliminary Checks:
11. When performing cruise test, touch "RECORD".
Consult Preliminary Checks:
12. After finishing cruise test part 1, touch "STOP".
Consult Preliminary Checks:
13. Touch "DISPLAY".
Consult Preliminary Checks:
14. Touch "PRINT".
Consult Preliminary Checks:
15. Touch "PRINT" again.
16. Check the monitor data printed out.
17. Continue cruise test part 2 and 3.