Turn Signal Operation
With the hazard switch in the OFF position and the ignition switch in the ON or START position, power is supplied^ Through 10 A fuse (No. 22 located in the fuse block)
^ To hazard switch terminal (2)
^ Through terminal (1) of the hazard switch
^ To combination flasher unit terminal (1)
^ Through terminal (3) of the combination flasher unit
^ To turn signal switch terminal (1).
Ground is supplied to combination flasher unit terminal (2) through body grounds (M1) and (M60).