With Multi Remote Control System
Power is supplied at all times^ through 10 A fuse (No. (17) located in the fuse block)
^ to multi-remote control relay terminal (1), (6) and (3)
Ground is supplied to multi-remote control relay terminal (2), when the multi-remote control system is triggered through the multi-remote control unit.
The multi-remote control relay is energized.
Power is supplied through terminal (7) of the multi-remote control relay
^ to front turn signal lamp RH terminal (1),
^ to rear combination lamp RH terminal (3) and
^ to combination meter terminal (32)
Power is supplied through terminal (5) of the multi-remote control relay
^ to front turn signal lamp LH terminal (1),
^ to rear combination lamp LH terminal (3) and
^ to combination meter terminal (6).
With power and ground supplied, the multi-remote control unit controls the flashing of the hazard warning lamps.