A/T - Control Cable Adjustment
9211infiniti01
Models: 1991 G20
Section: Amendments
Classification: AM90-004
Bulletin No.: ITB90-035
Date: December 21, 1990
G20 A/T CONTROL CABLE ADJUSTMENT
The following procedure for adjusting the automatic transaxle control cable is an amendment to the procedure given in the Service Manual. Please reference this Bulletin on page AT-8 of the 1991 G20 Service Manual, July 1990 (01) printing.
ON-VEHICLE SERVICE
Control Cable Installation and Adjustment
Move selector lever from the "P" range to "1" range. You should be able to feel the detents in each range. If the detents cannot be felt or the pointer indicating range is improperly aligned, the control cable needs adjustment.
1. Remove center console.
2. Loosen heater duct.
3. Locate control cable by sliding it through body and under heater duct.
Control Cable Installation and Adjustment
^ Move selector lever from the "P" range to the "1" range. You should be able to feel the detents in each range. It the detents cannot be felt or the pointer indicating the range is improperly aligned, the control cable needs adjustment.
^ Always adjust control cable when control cable is removed from selector lever or manual shaft.
INSTALLATION
1. Place selector lever and manual shaft at "P" position.
2. Attach control cable to selector lever and tighten control cable lock nut. Clamp control cable to selector lever bracket.
3. Attach control cable to manual shaft and clamp control cable to bracket at transaxle.
4. Pull control cable in the direction of the arrow shown in the illustration by specified force.
Specified force: 6.9 N (0.7 kg, 1.5 lb)
5. Return control cable in the opposite direction of the arrow for 1.0 mm (0.039 in).
6. Tighten control cable lock nut.
7. Move selector lever from "P" range to "1" range and make sure that selector lever can be moved smoothly and without any sliding noise.
8. Apply grease to contacting areas of selector lever and control cable. Install any part removed.
ADJUSTMENT
1. Loosen control cable lock nut at transaxle side.
2. Place selector lever and manual shaft at "P" position.
3. Pull control cable in the direction of the arrow shown in the illustration by specified force.
Specified force: 6.9 N (0.7 kg, 1.5 lb)
4. Return control cable in the opposite direction of the arrow for 1.0 mm (0.039 in).
5. Tighten control cable lock nut.
6. Move selector lever from "P" range to "1" range and make sure that selector lever can be moved smoothly and without any sliding noise.
7. Apply grease to contacting areas of selector lever and control cable.