Neutral Safety Switch: Testing and Inspection
Fig. 207 Inhibitor Switch Terminal Identification:
Check continuity between terminals A and B, Fig. 207.
1. With gear selector in Park position, continuity should exist between terminals A and B.
2. With gear selector in Neutral position, continuity should exist between terminals A and B.
3. With gear selector in any position except Park or Neutral, no continuity should exist between A and B.