B3130
DTC B3130
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions)provides an overview of each diagnostic category.
DTC Descriptor
DTC B3130 00
- All Door Unlock Circuit
Circuit/System Description
The body control module (BCM) energizes the unlock relay coil through a low side drive control circuit. When the BCM receives an unlock message the door unlock relay control circuit is grounded energizing the unlock relay coil.
Conditions for Running the DTC
* Battery voltage is between 9-16 volts.
* The BCM has attempted to energize the unlock relay.
Conditions for Setting the DTC
The door unlock relay control circuit is shorted to voltage.
Action Taken When the DTC Sets
The BCM will not attempt unlock operation.
Conditions for Clearing the DTC
* When the output request is not active the DTC will be a history status code.
* The history code will clear after 50 fault free ignition cycles or by using the scan tool clear DTCs feature.
Reference Information
Schematic Reference
Door Lock/Indicator Schematics (Door Lock/Indicator Schematics)
Connector End View Reference
Component Connector End Views (Component Connector End Views)
Description and Operation
Power Door Locks Description and Operation (Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Programming and Relearning (Programming and Relearning)for Scan Tool Information
Circuit/System Testing
1. Disconnect the IP fuse block and connect a test lamp from the door unlock relay control circuit terminal A3 in connector X3 to ground.
2. Ignition ON, verify that the test lamp does not illuminate.
• If the test lamp illuminates test the control circuit for a short to voltage. If the circuit tests normal replace the BCM.
3. If the circuits test normal replace the IP fuse block.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Instrument Panel Electrical Center or Junction Block Replacement - Left Side (Instrument Panel Electrical Center or Junction Block Replacement - Left Side)
* Programming and Relearning (Programming and Relearning)for BCM replacement, programming, and setup