Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

CVT Driven Pulley Pressure Control Solenoid Valve Test




CVT Driven Pulley Pressure Control Solenoid Valve Test

1. Remove the air cleaner Service and Repair.

2. Disconnect the solenoid wire harness connector (A).





3. Measure the CVT driven pulley pressure control solenoid valve resistance between solenoid wire harness connector (B) terminals No. 2 and No. 6.





4. If the resistance is out of standard, check for open or short in the solenoid wire harness. If the wires are OK, replace the CVT driven pulley pressure control solenoid valve CVT Driven Pulley Pressure Control Solenoid Valve Replacement.

5. Connect a jumper wire from the battery positive terminal to solenoid wire harness connector terminal No. 2, and connect another jumper wire from the battery negative terminal to terminal No. 6. A clicking sound should be heard.

6. If no clicking sound is heard, remove the CVT driven pulley pressure control solenoid valve, and clean it, then recheck. Replace the CVT driven pulley pressure control solenoid valve if a problem recurs CVT Driven Pulley Pressure Control Solenoid Valve Replacement.