CVT Driven Pulley Pressure Control Solenoid Valve Replacement




CVT Driven Pulley Pressure Control Solenoid Valve Replacement

1. Remove the lower valve body Lower Valve Body Removal/Installation.

2. Disconnect the CVT driven pulley pressure control solenoid valve connector (A) and the inhibitor solenoid connector (B).





3. Remove the CVT driven pulley pressure control solenoid valve (C), the dowel pins (D), and the separator plate (E), and remove the inhibitor solenoid (F) from the CVT driven pulley pressure control solenoid valve.

4. Check that the filter (G) is in good condition, replace it if it is clogged or damaged.

5. Remove the O-rings (H) from the inhibitor solenoid.

6. Install new O-rings on the inhibitor solenoid, then install the inhibitor solenoid on a new CVT driven pulley pressure control solenoid valve.

7. Install a new CVT driven pulley pressure control solenoid valve with the dowel pins and the separator plate on the lower valve body (I).

8. Connect the CVT driven pulley pressure control solenoid valve connector and the inhibitor solenoid connector.

9. Install the lower valve body Lower Valve Body Removal/Installation.