Torque Converter Housing Countershaft Bearing Replacement
Torque Converter Housing Countershaft Bearing Replacement
Special Tools Required
- Adjustable Bearing Puller, 25-40 mm 07736-A01000B
- Driver Handle, 15 x 135L 07749-0010000
- Bearing Driver Attachment, 62 x 68 mm 07746-0010500
1. Remove the countershaft bearing using the adjustable bearing puller and a commercially available 3/8''-16 slide hammer (A).
2. Install the ATF guide plate (A).
3. Install a new countershaft bearing (B) in the housing using the driver handle and the 62 x 68 mm bearing driver attachment; install the bearing outer race surface in height (C) of 0-0.03 mm (0-0.001 in) above the housing surface (D). Do not install the bearing exceeding 0.03 mm (0.001 in) high from housing surface.