Transmission Position Sensor/Switch: Testing and Inspection
Transmission Range Switch Test1. Remove the air cleaner assembly and the intake air duct.
2. Disconnect the transmission range switch connector.
3. Check for continuity between terminals at the switch connector. There should be continuity between the terminals in the following table for each switch position.
4. Transmission range switch test is completed if the test results are OK. If there is no continuity between any terminals, go to step 5.
5. Remove the transmission range switch, and check the end of the selector control shaft (A).
6. If the measurement of the selector control shaft end is within the standard, replace the transmission range switch. If the measurement is out of the standard, repair the selector control shaft end, and recheck the transmission range switch continuity.