Compressor Motor Power Control Module: Service and Repair
A/C Compressor Driver Removal/InstallationNOTE: Put on gloves to protect your hands.
IMA components are located in this area. The IMA is a high-voltage system. You must be familiar with the IMA system before working on or around it. Make sure you have read the IMA service precaution before doing repairs or service.
1. Remove the IPU lid.
2. Disconnect the A/C compressor power cables (A) from the terminal stay, then wrap them with insulating tape (B).
NOTE: Check the position of the U phase, V phase, and W phase cables before disconnecting the A/C compressor motor power cables.
3. Disconnect A/C compressor driver connector (A), and wires (B).
4. Remove the A/C compressor driver (C).
5. Install the parts in the reverse order of removal.