Fuel System Manual Control Valve (CNG): Service and Repair
Manual Shut-off Valve Replacement1. Relieve fuel pressure between the engine and the fuel tank.
2. Lift the vehicle, and support it with jackstands.
3. Remove the under-floor cover (A).
4. Disconnect the fuel lines (A).
NOTE: Always use two wrenches when removing or installing the fuel pipe nut.
5. Remove the bolt (B) and the manual shut-off valve.
6. Apply silicone grease (PARKER CHRISTO-LUBE) to a new O-rings (D) and carefully install it into its proper position.
7. Install the valve in the reverse order of removal.