CVT Drive Pulley Pressure Control Valve Solenoid Test
CVT Drive Pulley Pressure Control Valve Solenoid Test1. Remove the air cleaner housing and intake air duct.
2. Disconnect the solenoid her ness connector.
3. Measure the CVT drive pulley pressure control valve solenoid resistance between solenoid harness connector terminals No. 3 and No.7.
Standard: 3.8 - 6.8 Ohms
4. Connect the battery positive terminal to solenoid harness connector terminal No. 3, and connect the battery negative terminal to terminal No. 7. A clicking sound should be heard.
5. If the test results are different from standard, remove the lower valve body.
6. If the resistance is out of standard, check for an open or a short in the solenoid harness. If the wires are OK, replace the CVT drive pulley pressure control valve.
7. If no sound is heard, remove the CVT drive pulley pressure control valve, and clean it, then recheck. Replace the CVT drive pulley pressure control valve if a problem recurs.