CVT Driven Pulley Pressure Control Valve Replacement
CVT Driven Pulley Pressure Control Valve Replacement1. Remove the lower valve body.
2. Disconnect the CVT driven pulley pressure control valve connector (A) and the inhibitor solenoid connector (B).
3. Remove the CVT driven pulley pressure control valve (C), and remove the inhibitor solenoid (D) from the CVT driven pulley pressure control valve.
4. Check that the filter (E) is in good condition, replace it if it is clogged or damaged.
5. Replace the O-rings (F) on the inhibitor solenoid, if necessary.
6. Install the inhibitor solenoid on the new CVT driven pulley pressure control valve.
7. Install the new CVT driven pulley pressure control valve with the dowel pins (G) and separator plate (H) on the lower valve body (I).
8. Connect the CVT driven pulley pressure control valve connector and the inhibitor solenoid connector.
9. Install the lower valve body.