Disassembly and Assembly
Blower Unit Component Replacement
Note these items when overhauling the blower unit:
- The recirculation control motor (A), blower motor cooling hose (B) (2-door), blower motor cover (C) (2-door), the blower motor (D) and the dust and pollen filter (E) can be replaced without removing the blower unit.
- Before reassembly, make sure the recirculation control linkage and doors move smoothly without binding.
- After reassembly, make sure the recirculation control motor runs smoothly.