Procedure
1. Cut the new key(s).2. Gather up all the keys for the car. (The immobilizer control unit accepts up to five keys.)
3. Connect the PGM Tester, then turn the ignition switch ON (II) with the master key or valet key.
4. Go into the immobilizer menu. (Do not use the "Generic OBD II" mode.)
5. Select REWRITE on the tester screen to bring up the rewriting menu.
6. From the rewriting menu, select IMMOBI (Immobilizer unit). Follow all screen prompts until you return to the rewriting menu.
7. From the rewriting menu, select ECM, and follow the screen prompts. (You will need the password code for this step.)
8. Start the engine with all master keys and valet keys. If any of the keys do not start the engine, you will have to repeat steps 3 through 8 for all of the keys.
9. When you are finished, put the learning key back into its plastic case, and return it to the customer.