Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Starter Solenoid: Testing and Inspection

Fig. 14 Starter Relay Terminal Locations:





1. Check hold in coil for continuity between S terminal and ground as shown in Fig. 14. Continuity should exist.