Starter Relay: Testing and Inspection
Fig. 5 Starter Relay Terminal Locations:
W/Manual Transmission
1. Remove and disconnect starter relay.
2. Apply battery voltage to C and D terminals of relay as shown in Fig. 5.
3. Check continuity between A and B terminals of relay, continuity should exist.
4. Disconnect battery voltage, there should be no continuity between A and B terminals of relay.
5. If relay does not operate as specified, replace relay.