Condenser Fan Motor Relay: Testing and Inspection
Relay TestNOTE: All A/C system relays are similar
1. Check for continuity between terminals (2) and (4).
2. Connect a 12 V battery across terminals (2) and (4)
There should be continuity between terminals (1) and (3).