Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Manifold Pressure/Vacuum Sensor: Specifications


Manifold Absolute Pressure/Output voltage chart
125 mm Hg (5 in. Hg) 2.5 Volts
250 mm Hg (10 in. Hg) 2.0 Volts
375 mm Hg (15 in. Hg) 1.5 Volts
500 mm Hg (20 in. Hg) 1.0 Volts
625 mm Hg (25 in. Hg) 0.5 Volts