Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Amperage

Normal Operating Voltage 12 Volts
Maximum Generator Output 55 Amps
Polarity Negative (-) Ground
No-Load Generator Speed 1,100 RPM
Regulator Voltage 14.7-15.0 Volts
Direction of Rotation Clockwise (Pulley Side)
Maximum Generator Speed 18,000 RPM
Temperature Range -30 - 80°C (-22 - 170°F)
Brush Length
Standard 16 mm (0.63")
Limit (Minimum) 2mm (0.08")
Condenser Capacity 0.5 micro F