Variable Valve Timing Solenoid: Service and Repair
Variable Camshaft Timing (VCT) Oil Control Solenoid - 4.6L (3V)
Removal and Installation
1. Remove the LH or RH valve cover. For additional information, refer to Engine.
2. Remove the bolt and the Variable Camshaft Timing (VCT) oil control solenoid.
- To install, tighten to 5 Nm (44 lb-in).
3. To install, reverse the removal procedure.