Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Refrigerant Oil

Item PAG Refrigerant Compressor Oil (R-134a Systems) YN-12-D
Specification WSH-M1C231-B
Fill Capacity 121 ml (4.1 fl oz)

Adding Refrigerant Oil After New Suction Accumulator or Receiver/Drier Replacement

NOTE: This refrigerant oil adding method is to be used when a new suction accumulator or receiver drier only has been installed. If a new A/C compressor and evaporator core orifice or Thermostatic Expansion Valve (TXV) have also been installed due to system contamination, refer to the appropriate heading.

1. Drill one 12.7 mm (1/2 in) hole in the old suction accumulator or receiver/drier cylinder and drain the oil into a clean measuring cup.

2. Add the same quantity of new PAG oil, plus the amount collected during refrigerant recovery and 60 ml (2 fl oz).


Adding Refrigerant Oil After Multiple Component Replacement After A/C System Contamination

NOTE: This refrigerant oil adding method is to be used when a new A/C compressor, suction accumulator or receiver drier and evaporator core orifice or TXV have been installed due to system contamination and the A/C system has been flushed.

1. If the new A/C compressor is shipped with a new clutch and pulley already installed, remove the shipping caps and rotate the new A/C compressor shaft 6 to 8 revolutions while collecting the oil in a clean measuring cup.

2. Add 60 ml (2 fl oz) directly to the new A/C compressor suction port.

3. Inject the total vehicle PAG oil capacity minus 60 ml (2 fl oz) to the low-side service port during system charging. For the total PAG oil capacity specification, refer to the Specifications table.