Programming and Relearning
ROOF OPENING PANEL MOTOR INITIALIZATIONInitializing a New Roof Opening Panel Motor
WARNING: Keep objects and body parts clear of the glass panel when carrying out the initialization procedure. During the initialization procedure, the glass panel closes with high force and cannot detect objects in its path. Failure to follow this instruction may result in serious personal injury.
NOTE:
- This procedure should only be carried out when the roof opening panel motor is connected.
- The roof opening panel alignment must be carried out prior to carrying out roof opening panel motor initialization. For additional information, refer to Roof Opening Panel Alignment. Adjustments
1. Press and hold the roof opening panel control switch in the up/close position until the roof opening panel moves slightly past full vent 2 mm (0.08 in) and the roof opening panel motor stops.
2. Quickly release the roof opening panel control switch and re-press and hold (within 0.5 second) until the roof opening panel returns to the full open position and then back to the fully closed position.
3. Release the roof opening panel control switch and verify successful initialization by performing one-touch open and one-touch close operations.
Re-Initializing an Existing Roof Opening Panel Motor
WARNING: Keep objects and body parts clear of the glass panel when carrying out the initialization procedure. During the initialization procedure, the glass panel closes with high force and cannot detect objects in its path. Failure to follow this instruction may result in serious personal injury.
NOTE:
- This procedure should only be carried out when the roof opening panel motor is connected.
- The roof opening panel alignment must be carried out prior to carrying out roof opening panel motor initialization. For additional information, refer to Roof Opening Panel Alignment. Adjustments
1. Operate the roof opening panel to the full vent position.
2. Press and hold the roof opening panel control switch in the up/close position (for approximately 30 seconds) until the roof opening panel moves slightly past full vent 2 mm (0.08 in) and the roof opening panel motor stops.
3. Quickly release the roof opening panel control switch and re-press and hold (within 0.5 second) until the roof opening panel moves to the full open position and then back to the fully closed position.
4. Release the roof opening panel control switch and verify successful initialization by performing one-touch open and one-touch close operations.