Test E: The Turn Signal Chime Is Inoperative/Does Not Operate Correctly
PINPOINT TEST E: THE TURN SIGNAL CHIME IS INOPERATIVE/DOES NOT OPERATE CORRECTLYE1-E3:
E3-E5:
E5-E8:
E8-E9:
Normal Operation
When the generic electronic module (GEM) senses that the turn signal switch is activated, the GEM supplies voltage to the multifunction switch over circuit 29S-LG43 (OG/WH), sounding the chime. Ground for the multifunction switch chime is supplied by circuit 91-LG43 (BK/WH).
Possible Causes
- Circuit 29S-LG43 (OG/WH) open, short to ground or voltage
- Circuit 91-LG43 (BK/WH) open
- Multifunction switch
- GEM