Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Updating Roof Opening Panel Motor Initialization

UPDATING ROOF OPENING PANEL MOTOR INITIALIZATION

WARNING: The roof opening panel anti-trap function will not operate during the roof opening panel motor initialization procedure. Make sure that the roof opening panel opening is free of all foreign material. Failure to follow these instructions may result in personal injury.

NOTE:
- This procedure should only be carried out when the roof opening panel motor is not disconnected.
- The roof opening panel alignment must be carried out prior to carrying out roof opening panel motor initialization.

1. Operate the roof opening panel control switch to the up/close position until the roof opening panel is in the fully open/vent position.
2. Release the roof opening panel control switch.
3. Press the roof opening panel control switch in the up/close position and hold for 30 seconds until there is a small movement of approximately 2 mm (0.08 in) and the roof opening panel motor stops.
4. Release the roof opening panel control switch.
5. Press the roof opening panel control switch in the up/close position again within 0.5 second until the roof opening panel stops (1 complete cycle).