Erasing Roof Opening Panel Motor Initialization
ERASING ROOF OPENING PANEL MOTOR INITIALIZATIONNOTE:
- The erasing procedure is to be carried out only when the roof opening panel motor is removed from the roof opening panel.
- This procedure must be carried out before installing a previously used roof opening panel motor.
1. Connect the roof opening panel motor electrical connector.
2. Operate the roof opening panel control switch to the up/close position until the roof opening panel motor stops.
3. Release the roof opening panel control switch.
4. Operate the roof opening panel control switch again to the up/close position and hold for 30 seconds. With the roof opening panel control switch held, the roof opening panel motor rotates in 1 direction.
5. Release the roof opening panel control switch.
6. Operate the roof opening panel control switch to the down/open position. If the roof opening panel motor does not rotate, the erasing procedure has been carried out successfully.
7. If the roof opening panel motor rotates (with the roof opening panel control switch in the down/open position), repeat the procedure.