Front Electronic Module (FEM)
FRONT ELECTRONIC MODULE (FEM)Removal and Installation
1. CAUTION:
- Prior to the removal of the FEM module, it is necessary to upload module configuration information to the appropriate diagnostic equipment. This information needs to be downloaded into the new module once it is installed.
- Electronic modules are sensitive to static electrical charges. If electronic modules are exposed to these charges, damage may result.
Disconnect the battery ground cable.
2. Remove the LH scuff plate.
3. Release the retaining clips and remove the LH A-pillar lower trim panel.
4. Position the carpet aside.
5. Remove the 2 nuts and position the auxiliary junction box aside.
6. Disconnect the FEM wiring harness connectors.
7. Remove the 2 FEM nuts.
- To install, tighten to 4 Nm (35 lb-in).
8. Remove the bolt and the FEM.
- To install, tighten to 9 Nm (80 lb-in).
9. To install, reverse the removal procedure.
- Once the FEM is installed, it is necessary to download the module configuration information from the diagnostic tool into the new module. Refer to Information Bus (Module Communications Network).