Replacement of the Weld Nut and Reinforcement
REPLACEMENT OF THE WELD NUT AND REINFORCEMENT1. NOTE: If the B, or C pillar safety belt anchor nuts or reinforcements are stripped or missing, a new nut/reinforcement plate must be installed.
Expose the suspect anchor point.
2. Drill out two 8-mm (5/16-inch) diameter access holes adjacent to the weld nut clearance hole.
3. Thread a length of copper welding wire through the clearance hole and position to secure the weld nut and washer.
4. Use MIG wire feed welder and plug weld a 7/16-inch weld nut and standard washer in place at the two 8-mm (5/16-inch) holes.
5. Metal finish as necessary.
6. Install the restraint system.
7. Carry out the Functional Tests. Component Tests and General Diagnostics