Initial Inspection - Instrument Panel Illumination
1. Verify the customer concern.2. Visually inspect for obvious signs mechanical or electrical damage.
VISUAL INSPECTION CHART
Electrical
^ Headlamp switch
^ Central Junction Box (CJB) fuse(s)
^ Connector(s)
^ Circuit(s)
^ Illumination bulb(s)
^ Climate control unit
^ Hazard switch
^ Headlamp switch
^ Dimmer switch (part of the headlamp switch)
^ Instrument cluster
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
4. If the concern is not visually evident, verify the symptom and refer to the Symptom Chart. Diagnosis By Symptom - Instrument Panel Illumination