Compressor HVAC: Service and Repair
REMOVALCAUTION:
- To prevent refrigerant system contamination, if you are installing a new A/C compressor because the compressor has failed internally, you must carry out the following procedures:
- If A/C Flusher is available, carry out the Flushing general procedure.
- If A/C flusher is not available, carry out the Refrigerant System Filtering After A/C Component Replacement general procedure.
- Install a new A/C evaporator core orifice.
1. Disconnect the battery.
2. Perform the Refrigerant Discharging and Recovery Procedure.
3. Remove the drive belt.
4. Raise the vehicle.
5. Disconnect the A/C compressor electrical connector.
6. Remove the manifold and tube assembly.
1 Remove the bolt.
2 Remove the manifold and tube assembly.
7. Remove the compressor.
1 Remove the bolts.
2 Remove the compressor.
INSTALLATION
1. To install, reverse the removal procedure.
- Service the new compressor with the correct amount of PAG Compressor Oil YN-12c, F7AZ-19589-DA or equivalent meeting Ford specification WSH-M1C231-B. See: Refrigerant Oil Addition.
- Lubricate the O-ring seal with PAG Compressor Oil. YN-12c, F7AZ-19589-DA or equivalent meeting Ford specification WSH-M1C231-B.
See: Refrigerant Oil Addition.