Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Peanut Fitting Connect and Disconnect Procedure

DISCONNECT
1. Perform the Refrigerant Discharging and Recovery Procedure.







2. Remove the nut from the peanut fitting.

CAUTION: Support the female fitting with a wrench to prevent the tubes from twisting.







3. Pull the peanut fitting apart.







4. Remove the O-ring seal with a non-metallic tool.

CAUTION: Do not use metal tools to remove the O-ring seal. They can cause axial scratches across the O-ring seal groove resulting in refrigerant leaks.

CONNECT

1. Clean all dirt or foreign material from the fittings.







2. Install the O-ring seal.
1. Lubricate the O-ring seals with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B.

CAUTION: Use only new purple O-ring seals. The use of any O-ring seals other than specified may result in intermittent leakage during vehicle operation.

3. Lubricate the inside of the fittings with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B.







4. Assemble the male and female fittings together.

NOTE: When correctly assembled, the male and female fittings should be flush.

5. Charge the system. Refer to Evacuation and Charging.