Component Tests and General Diagnostics
SPECIAL SERVICE TOOL(S)
CAUTION: The evaporative emission system must not be pressurized to more than 3.48 kPa (14 inches/H2O) or damage to the evaporative emission system may occur.
1. Connect the Evaporative Emission System Leak Tester to the evaporative emission test port.
2. Close tile [1][2]canister vent solenoid. For additional information, refer to Canister Vent Solenoid Closing Procedure. Canister Vent Solenoid Closing Procedure
3. Pressurize the evaporative emission system to 3.48 kPa (14 inches/H2O).
4. Monitor the system for two minutes. The system fails the leak test if the pressure falls below 2.0 kPa (8 inches/H2O).
5. Repair any leaks as necessary.
6. Repeat the leak test until the system remains above 2.0 kPa (8 inches/H2O) after the two-minute test period.