Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oil Pump

General
Clearance
Rotor to Housing Side 0.030-0.090 mm (0.0012-0.0035 inch)
Outer Rotor to Housing Radial 0.100-0.175 mm (0.0039-0.0069 inch)
Inner Rotor Shaft to Housing 0.030-0.095 mm (0.0012-0.0037 inch)
End Play (Clearance), Max 0.030-0.090 mm (0.0012-0.0035 inch)
Rotor Tip Clearance
Outer and Inner 0.060-0.180 mm (0.0024-0.0071 inch)

Tightening Specifications
Retaining Bolts 9-13 Nm (80-115 inch lbs.)