Electrical Specifications
Transmission Range Selector Lever Position ResistancePARK
Minimum 3770 Ohms
Maximum 4607 Ohms
REVERSE
Minimum 1304 Ohms
Maximum 1593 Ohms
NEUTRAL
Minimum 660 Ohms
Maximum 807 Ohms
OVERDRIVE [a]
Minimum 361 Ohms
Maximum 442 Ohms
SECOND/DRIVE [b]
Minimum 190 Ohms
Maximum 232 Ohms
MANUAL 1
Minimum 78 Ohms
Maximum 95 Ohms
[a] Same values for overdrive or O/D CANCEL (DRIVE) on electronically controlled transmissions. D and Drive (O/D Cancelled) are in the same transmission range selector lever position.
[b] Same values for SECOND (electronic transmission) or DRIVE on transmissions with a separate DRIVE and OVERDRIVE position.