Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

E6 Check Motor Operation







CAUTION: While performing this test step, do not allow motor to operate for more than two seconds.

- Hydraulic anti-lock actuator assembly connector C2 disconnected.

- Apply battery voltage to the "R/Y" terminal and ground the "BK" terminal at the hydraulic anti-lock actuator assembly connector C2.

- Does the motor operate when voltage is applied?

YES -- Go to E7. E7 Check Motor Ground

NO -- Replace hydraulic anti-lock actuator assembly.