Right Side
1. Remove air cleaner outlet tube.2. Disconnect secondary air injection tube.
3. Remove upper mounting nuts from exhaust manifold.
4. Raise and support vehicle.
5. Remove dual converter Y pipe.
6. Remove lower exhaust manifold mounting nuts, then manifold. Discard gaskets.
7. Reverse procedure to install, noting following:
a. Ensure mating surfaces are clean and free of burrs and gouges.
Fig. 6 Right exhaust manifold tightening sequence:
b. Tighten exhaust manifold bolts to 13-16 ft lb in sequence.