STP2 - Power to Switch
- Key OFF.
- Disconnect the connector of the switch in question.
- Key ON.
- Measure the voltage at the PWR terminal on the harness connector of the switch in question.
- Is the voltage approximately battery voltage?
Yes -- Go to STP3. STP3 - Switch Continuity
No -- Service the PWR wire for open(s).