Turn Signals: Description and Operation
Voltage is present at all times at pin H of the Flasher Module through the HAZARD Fuse, circuit 81 (BR). With the
Turn Signal Switch toward "LEFT", battery voltage is applied to the Flasher Module via circuit 116 (GY/BK). With this switch toward "RIGHT", voltage is applied to the Module via circuit 117 (GY/W). The Flasher Module then applies a pulsing voltage to the respective turn lights. When the Hazard Switch is in the "ON" position, circuit 115 (GN/R) to the Flasher Module is grounded. The Flasher Module then applies pulsing voltage from circuit 81 (BR) to the Turn Lamps.