Blower Motor: Service and Repair
1. On models equipped with airbag, disarm airbag system as described under MAINTENANCE PROCEDURES/AIRBAG SYSTEM DISARMING.2. On all models, disconnect battery ground cable and isolate cable end with electrical tape.
3. Loosen glove compartment assembly by squeezing sides of glove compartment together to disengage retainer tabs.
4. Let glove compartment and door hang in front of instrument panel.
5. Remove blower motor cooling hose.
6. Remove four screws that retain blower motor assembly to blower motor housing.
7. Disconnect electrical connector from wiring harness.
8. Carefully pull blower motor assembly from housing.
9. Reverse procedure to install.
10. On models equipped with airbag, reactivate airbag system.