Oxygen Sensor: Service and Repair
*** THIS ARTICLE REFLECTS CHANGES MADE BY TSB #93236, DATED NOVEMBER 10, 1993REMOVAL
1. Disconnect negative battery cable.
2. Disconnect sensor electrical connector.
3. Using a suitable wrench, remove sensor.
INSTALLATION
1. Install sensor. Tighten to 22 - 36 ft lb (29 - 49 Nm).
2. Plug in electrical connector.
3. Connect negative battery cable.