KF - Testing Notes
NOTE: You should enter this Pinpoint Test only when you have been directed here from Quick Test or Diagnosis By Symptom.REMEMBER
To prevent the replacement of good components, be aware that the following non-EEC areas may be at fault.
- Harness circuits: EDF, HEDF, EDF Power-To-Fan, HEDF Power-To-Fan, IGN Start/Run and GND.
- EDF Relay
- HEDF Relay
- Cooling Fan
- Processor assembly
DESCRIPTION
Electro Drive Fan/High Electro Drive Fan:
The EEC-IV processor determines engine cooling fan requirements and controls the fan operation through the EDF and HEDF outputs. The HEDF and EDF are normally open relays.
BOTH FANS OFF
The HEDF and EDF outputs are off.
EDF ON
The EDF output is turned on, closing the normally open EDF relay. The HEDF output is off, and BATT(+) is supplied to the EDF relay through the HEDF relay.
HEDF ON
The HEDF output is on, which closes the HEDF relay. With the HEDF relay contacts closed, BATT(+) is not longer supplied to the EDF relay, Preventing both fan speeds from being activated at the same time.