Alternator: Service and Repair
REMOVAL1. Disconnect negative battery cable.
Generator:
2. Loosen lower mounting bolt do not remove.
3. Loosen pivot bolt, but do not remove.
4. Loosen belt adjustment bolt.
5. Remove the generator drive belt.
6. Remove bracket.
7. Remove lower mounting bolt.
8. Remove pivot bolt.
9. Remove generator.
10. Disconnect the generator field circuit plug.
Wire Terminal Connection:
11. Remove the B+ terminal nut and wire.
INSTALLATION
1. For installation, reverse above procedures. Tighten the fasteners to the proper torque. Refer to the Torque Specifications chart.