ABS Main Relay: Testing and Inspection
Fig 93 Power Relay Location And Terminal Identification:
1. Remove instrument panel under cover, then the power relay.
2. Check for continuity across power relay terminals as shown.
Fig 94 BS Power Relay Continuity Inspection:
3. Compare results.
4. If continuity is not as specified, replace power relay.