Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Ignition Coil Test





1. Measurement of the primary coil resistance - Measure the resistance of the positive terminal 11 and negative terminal 12 of the ignition coil.

Standard value: 0.9 - 1.2 K ohms

2. Measurement of the secondary coil resistance - Measure the resistance of the positive terminal 11 and the high voltage terminal.

Standard value: 20 - 29 K ohms