Mechanical Specifications





IDLE SPEED

Normal idle (ISC operating) 750 - 800 RPM
With ISC fully extended (using tool 7088) 3500 RPM



IGNITION TIMING

The ignition timing is controlled by the ECU and is not adjustable.



TORQUE VALUES

Component Torque


Catalytic Converter (front nuts) 25 ft lbs (34 Nm)

Catalytic Converter (rear clamp nuts) 40 ft lbs (61 Nm)

EGR Mounting Bolts 20 ft lbs (27 Nm)

EGR Tube Nut 30 ft lbs (41 Nm)

EGR Tube Bolts 14 ft lbs (19 Nm)

Oxygen Sensor 22 ft lbs (30 Nm)