Non-Linear Vacuum Regulator (NLVR)





1. Connect a vacuum gauge to distributor port (Dist.) of NLVR.
2. With engine idling, a vacuum reading of 7 in. Hg. should be indicated.
3. Gradually, open throttle. As engine speed increases, ported vacuum from the carburetor should be indicated on the vacuum gauge.