Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Air Inlet Housing






HOUSING-AIR INLET

WARNING: Refer to the applicable warnings and cautions for this system before performing the following operation Warning and Caution . Failure to follow the warnings and cautions could result in possible serious or fatal injury.

NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.





1. Disconnect and isolate the negative battery cable.
2. Remove the HVAC housing assembly HVAC Housing - Removal.
3. Disconnect the HVAC wire harness (1) from the recirculation door actuator (2).
4. Carefully cut the foam seal (3) along the parting line (4) of the air inlet housing (6). If the seal is deformed or damaged, it must be replaced.
5. Remove the five screws (5) that secure the air inlet housing to HVAC housing (7).
6. Remove the air inlet housing from the HVAC housing.
7. If required, disassemble the air inlet housing HVAC Housing - Disassembly.